Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DM-6,3-M7(24VDC)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Power consumption
2.6W
Depth
76mm
Suitable for emergency stop
Rated operation power at AC-3, 400 V
2.2kW
Width
45mm
Number of auxiliary contacts as normally closed contact
0
Number of command positions
0
Number of auxiliary contacts as normally open contact
1
Rated operation current Ie
5A
Overload release current setting
4 .. 6.3A
Height
170mm
Number of indicator lights
0
Supporting protocol for TCP/IP
Supporting protocol for ASI
With transformer
Supporting protocol for LON
Supporting protocol for Modbus
Supporting protocol for INTERBUS
Rail mounting possible
External reset possible
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Supporting protocol for SUCONET
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Degree of protection (IP)
IP20
Supporting protocol for CAN
Supporting protocol for Data-Highway
Rated control supply voltage Us at DC
24 .. 24V
With short-circuit release
Supporting protocol for SERCOS
Release class
CLASS 10 A
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Supporting protocol for other bus systems
Supporting protocol for DeviceNet
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
With fuse
Supporting protocol for EtherNet/IP
Supporting protocol for PROFIBUS
Rated operation current at AC-3, 400 V
6.3A
Type of motor starter
Direct online starter (DOL)
Coordination class according to IEC 60947-4-3
Class 2
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 2, 400 V
50000A
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for PROFINET IO
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Voltage type for actuating
DC
Degree of protection (NEMA)
Other
Temperature compensated overload protection
Supporting protocol for PROFINET CBA
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A