Technical specifications
Rated operation power at AC-3, 400 V
2.2kW
Rated control supply voltage Us at DC
24 - 24V
With short-circuit release
Yes
Rated control supply voltage Us at AC 50HZ
0 - 0V
Voltage type for actuating
DC
Rated control supply voltage Us at AC 60HZ
0 - 0V
Type of motor starter
Direct online starter (DOL)
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
4 - 6.3A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rail mounting possible
No
Rated operation current Ie
5A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
6.3A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 400 V
50000A
Ambient temperature, upper operating limit
55°C
Power consumption
2.6W
Temperature compensated overload protection
Yes
Number of auxiliary contacts as normally open contact
1
External reset possible
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of command positions
0
Number of indicator lights
0
Type of electrical connection of main circuit
Screw connection
Degree of protection (NEMA)
Other
With fuse
No
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
No
Release class
CLASS 10 A
Coordination class according to IEC 60947-4-3
Class 2
With transformer
No
Suitable for emergency stop
No
Supporting protocol for PROFIBUS
No
Rated power, 575 V, 60 Hz, 3-phase
0kW
Supporting protocol for ASI
No
Supporting protocol for INTERBUS
No
Supporting protocol for CAN
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Width
45mm
Height
170mm
Depth
76mm
Supporting protocol for Modbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Data-Highway
No
From same serie
MSC-DM-6,3-M7(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated operation power at AC-3, 400 V
2.2kW
Rated control supply voltage Us at DC
24 .. 24V
With short-circuit release
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Voltage type for actuating
DC
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Type of motor starter
Direct online starter (DOL)
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
4 .. 6.3A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rail mounting possible
Rated operation current Ie
5A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
6.3A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 400 V
50000A
Ambient temperature, upper operating limit
55°C
Power consumption
2.6W
Temperature compensated overload protection
Number of auxiliary contacts as normally open contact
1
External reset possible
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of command positions
0
Number of indicator lights
0
Type of electrical connection of main circuit
Screw connection
Degree of protection (NEMA)
Other
With fuse
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
Release class
CLASS 10 A
Coordination class according to IEC 60947-4-3
Class 2
With transformer
Suitable for emergency stop
Supporting protocol for PROFIBUS
Rated power, 575 V, 60 Hz, 3-phase
0kW
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for CAN
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Width
45mm
Height
170mm
Depth
76mm
Supporting protocol for Modbus
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet
Supporting protocol for Foundation Fieldbus
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for SERCOS
Supporting protocol for PROFINET IO
Supporting protocol for Data-Highway
From same serie