Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Power consumption2.6W
Depth76mm
Suitable for emergency stopNo
Rated operation power at AC-3, 400 V2.2kW
Width45mm
Number of auxiliary contacts as normally closed contact0
Number of command positions0
Number of auxiliary contacts as normally open contact1
Rated operation current Ie5A
Overload release current setting4 - 6.3A
Height170mm
Number of indicator lights0
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
With transformerNo
Supporting protocol for LONNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Rail mounting possibleNo
External reset possibleNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Degree of protection (IP)IP20
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Rated control supply voltage Us at DC24 - 24V
With short-circuit releaseYes
Supporting protocol for SERCOSNo
Release classCLASS 10 A
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Type of electrical connection of main circuitScrew connection
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
With fuseNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFIBUSNo
Rated operation current at AC-3, 400 V6.3A
Type of motor starterDirect online starter (DOL)
Coordination class according to IEC 60947-4-3Class 2
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 400 V50000A
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 230 V50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Voltage type for actuatingDC
Degree of protection (NEMA)Other
Temperature compensated overload protectionYes
Supporting protocol for PROFINET CBANo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DM-6,3-M7(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Power consumption

2.6W

Depth

76mm

Suitable for emergency stop

Rated operation power at AC-3, 400 V

2.2kW

Width

45mm

Number of auxiliary contacts as normally closed contact

0

Number of command positions

0

Number of auxiliary contacts as normally open contact

1

Rated operation current Ie

5A

Overload release current setting

4 .. 6.3A

Height

170mm

Number of indicator lights

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

With transformer

Supporting protocol for LON

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Rail mounting possible

External reset possible

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for SUCONET

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Degree of protection (IP)

IP20

Supporting protocol for CAN

Supporting protocol for Data-Highway

Rated control supply voltage Us at DC

24 .. 24V

With short-circuit release

Supporting protocol for SERCOS

Release class

CLASS 10 A

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

With fuse

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIBUS

Rated operation current at AC-3, 400 V

6.3A

Type of motor starter

Direct online starter (DOL)

Coordination class according to IEC 60947-4-3

Class 2

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 400 V

50000A

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Voltage type for actuating

DC

Degree of protection (NEMA)

Other

Temperature compensated overload protection

Supporting protocol for PROFINET CBA

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.