Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DME-1,2-M17(24VDC)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Number of command positions
0
Depth
149.5mm
Rated operation power at AC-3, 400 V
1.1kW
Width
45mm
Suitable for emergency stop
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
1
Height
206mm
With transformer
Supporting protocol for PROFIBUS
Overload release current setting
0.3 .. 1.2A
Number of indicator lights
0
External reset possible
Rated operation current Ie
1.2A
Supporting protocol for SERCOS
Supporting protocol for other bus systems
With short-circuit release
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for LON
Supporting protocol for Data-Highway
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Supporting protocol for ASI
Degree of protection (IP)
IP20
Release class
Adjustable
Rail mounting possible
Supporting protocol for CAN
Supporting protocol for DeviceNet
Supporting protocol for Modbus
Rated control supply voltage Us at AC 60HZ
0 .. 0V
With fuse
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for SUCONET
Supporting protocol for INTERBUS-Safety
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Supporting protocol for DeviceNet Safety
Type of electrical connection of main circuit
Screw connection
Supporting protocol for EtherNet/IP
Supporting protocol for PROFIsafe
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
1.2A
Supporting protocol for Foundation Fieldbus
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Temperature compensated overload protection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for SafetyBUS p
Supporting protocol for PROFINET IO
Supporting protocol for AS-Interface Safety at Work
Rated conditional short-circuit current, type 2, 400 V
100000A
Voltage type for actuating
DC
Ambient temperature, upper operating limit
55°C
Rated power, 460 V, 60 Hz, 3-phase
0kW
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
0.18kW
Rated conditional short-circuit current, type 2, 230 V
100000A
Supporting protocol for PROFINET CBA
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (NEMA)
Other