Technical specifications
MSC-DME-12-M17(24VDC)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
45mm
Number of auxiliary contacts as normally open contact
1
Rated operation current Ie
11.3A
With transformer
Number of indicator lights
0
Number of command positions
0
Number of auxiliary contacts as normally closed contact
0
Depth
149.5mm
Rated operation power at AC-3, 400 V
5.5kW
Height
206mm
Supporting protocol for Modbus
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for other bus systems
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Supporting protocol for DeviceNet
External reset possible
Supporting protocol for LON
Supporting protocol for Data-Highway
Supporting protocol for ASI
Overload release current setting
8 .. 12A
Supporting protocol for SUCONET
Supporting protocol for PROFIBUS
Rail mounting possible
Suitable for emergency stop
Supporting protocol for PROFINET CBA
Rated operation power at AC-3, 230 V, 3-phase
3kW
Rated control supply voltage Us at AC 60HZ
0 .. 0V
With fuse
Supporting protocol for PROFINET IO
Degree of protection (IP)
IP20
Supporting protocol for EtherNet/IP
Release class
Adjustable
With short-circuit release
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Type of electrical connection of main circuit
Screw connection
Supporting protocol for DeviceNet Safety
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Type of motor starter
Direct online starter (DOL)
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for INTERBUS-Safety
Supporting protocol for SERCOS
Ambient temperature, upper operating limit
55°C
Rated operation current at AC-3, 400 V
12A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 400 V
100000A
Coordination class according to IEC 60947-4-3
Class 2
Temperature compensated overload protection
Degree of protection (NEMA)
Other
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 230 V
100000A