Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Yes
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rated control supply voltage Us at DC
0 - 0V
Voltage type for actuating
AC
Rated operation power at AC-3, 400 V
12.5kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated operation current Ie
21.7A
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
25A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Type of electrical connection of main circuit
Screw connection
Overload release current setting
8 - 32A
With transformer
No
Rail mounting possible
No
Release class
Adjustable
Coordination class according to IEC 60947-4-3
Class 2
Temperature compensated overload protection
Yes
Number of command positions
0
Rated operation power at AC-3, 230 V, 3-phase
5.5kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
100000A
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for DeviceNet Safety
No
Number of auxiliary contacts as normally open contact
1
Ambient temperature, upper operating limit
55°C
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for emergency stop
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Width
45mm
Supporting protocol for other bus systems
No
Height
206mm
Depth
149.5mm
Supporting protocol for SUCONET
No
Degree of protection (NEMA)
Other
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Number of indicator lights
0
Supporting protocol for INTERBUS
No
With fuse
No
External reset possible
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Degree of protection (IP)
IP20
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for ASI
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Modbus
No
From same serie
MSC-DME-32-M25(230V50HZ)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated control supply voltage Us at DC
0 .. 0V
Voltage type for actuating
AC
Rated operation power at AC-3, 400 V
12.5kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated operation current Ie
21.7A
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
25A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Type of electrical connection of main circuit
Screw connection
Overload release current setting
8 .. 32A
With transformer
Rail mounting possible
Release class
Adjustable
Coordination class according to IEC 60947-4-3
Class 2
Temperature compensated overload protection
Number of command positions
0
Rated operation power at AC-3, 230 V, 3-phase
5.5kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
100000A
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for DeviceNet Safety
Number of auxiliary contacts as normally open contact
1
Ambient temperature, upper operating limit
55°C
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for emergency stop
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Width
45mm
Supporting protocol for other bus systems
Height
206mm
Depth
149.5mm
Supporting protocol for SUCONET
Degree of protection (NEMA)
Other
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Number of indicator lights
0
Supporting protocol for INTERBUS
With fuse
External reset possible
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Degree of protection (IP)
IP20
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for DeviceNet
Supporting protocol for SERCOS
Supporting protocol for PROFINET IO
Supporting protocol for Modbus
From same serie