- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DME-32-M25(24VDC)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Number of indicator lights
0
Rated operation current Ie
21.7A
Number of command positions
0
Depth
149.5mm
Supporting protocol for LON
Number of auxiliary contacts as normally open contact
1
Height
206mm
Suitable for emergency stop
Width
45mm
With transformer
Supporting protocol for TCP/IP
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
8 .. 32A
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for SUCONET
Supporting protocol for INTERBUS
Rated operation power at AC-3, 400 V
12.5kW
Supporting protocol for PROFIBUS
Supporting protocol for other bus systems
Rail mounting possible
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for INTERBUS-Safety
Rated control supply voltage Us at AC 50HZ
0 .. 0V
With fuse
With short-circuit release
Rated control supply voltage Us at AC 60HZ
0 .. 0V
External reset possible
Release class
Adjustable
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for SafetyBUS p
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Type of motor starter
Direct online starter (DOL)
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Type of electrical connection of main circuit
Screw connection
Supporting protocol for PROFIsafe
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
5.5kW
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
25A
Degree of protection (NEMA)
Other
Coordination class according to IEC 60947-4-3
Class 2
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
100000A
Temperature compensated overload protection