Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DME-32-M32(24VDC)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
45mm
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie
29.3A
Rated operation power at AC-3, 400 V
15kW
Number of command positions
0
With transformer
Depth
149.5mm
Supporting protocol for PROFIBUS
Suitable for emergency stop
Supporting protocol for INTERBUS
Height
206mm
Supporting protocol for TCP/IP
Number of indicator lights
0
Supporting protocol for CAN
Number of auxiliary contacts as normally open contact
1
Supporting protocol for ASI
Supporting protocol for LON
Overload release current setting
25 .. 32A
Supporting protocol for other bus systems
Rail mounting possible
Supporting protocol for Modbus
Rated control supply voltage Us at AC 50HZ
0 .. 0V
External reset possible
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for SERCOS
With short-circuit release
Degree of protection (IP)
IP20
Release class
Adjustable
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for PROFINET CBA
Voltage type for actuating
DC
Type of motor starter
Direct online starter (DOL)
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET IO
Supporting protocol for EtherNet/IP
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for SafetyBUS p
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Type of electrical connection of main circuit
Screw connection
With fuse
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Rated operation current at AC-3, 400 V
32A
Ambient temperature, upper operating limit
55°C
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Supporting protocol for INTERBUS-Safety
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 230 V
100000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Temperature compensated overload protection
Degree of protection (NEMA)
Other