Aleta.hr
Main Product Image

MSC-DME-4-M17(24VDC)

Code: 1957918

ManufacturerRAZNO
Catalog number192760
Type
EAN code4015081935048

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 50HZ

0 - 0V

Rated operation power at AC-3, 400 V

3.6kW

Rated control supply voltage Us at DC

24 - 24V

Voltage type for actuating

DC

Type of motor starter

Direct online starter (DOL)

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.75kW

With short-circuit release

Yes

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Overload release current setting

1 - 4A

Rated conditional short-circuit current, type 2, 400 V

100000A

Rated operation current Ie

4A

Rated conditional short-circuit current, type 2, 230 V

100000A

Release class

Adjustable

Number of auxiliary contacts as normally open contact

1

Temperature compensated overload protection

Yes

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated operation current at AC-3, 400 V

4A

Number of auxiliary contacts as normally closed contact

0

Rated power, 460 V, 60 Hz, 3-phase

0kW

Ambient temperature, upper operating limit

55°C

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for other bus systems

No

Supporting protocol for SafetyBUS p

No

Width

45mm

Height

206mm

Depth

149.5mm

Rail mounting possible

No

With transformer

No

Suitable for emergency stop

No

Number of command positions

0

Number of indicator lights

0

Coordination class according to IEC 60947-4-3

Class 2

External reset possible

No

With fuse

No

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

No

Supporting protocol for PROFIBUS

No

Supporting protocol for CAN

No

Supporting protocol for Modbus

No

Supporting protocol for SUCONET

No

Supporting protocol for DeviceNet

No

Supporting protocol for ASI

No

Supporting protocol for Data-Highway

No

Supporting protocol for SERCOS

No

Supporting protocol for LON

No

Supporting protocol for PROFINET IO

No

Supporting protocol for INTERBUS

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for AS-Interface Safety at Work

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DME-4-M17(24VDC)

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated operation power at AC-3, 400 V

3.6kW

Rated control supply voltage Us at DC

24 .. 24V

Voltage type for actuating

DC

Type of motor starter

Direct online starter (DOL)

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.75kW

With short-circuit release

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Overload release current setting

1 .. 4A

Rated conditional short-circuit current, type 2, 400 V

100000A

Rated operation current Ie

4A

Rated conditional short-circuit current, type 2, 230 V

100000A

Release class

Adjustable

Number of auxiliary contacts as normally open contact

1

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation current at AC-3, 400 V

4A

Number of auxiliary contacts as normally closed contact

0

Rated power, 460 V, 60 Hz, 3-phase

0kW

Ambient temperature, upper operating limit

55°C

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

Width

45mm

Height

206mm

Depth

149.5mm

Rail mounting possible

With transformer

Suitable for emergency stop

Number of command positions

0

Number of indicator lights

0

Coordination class according to IEC 60947-4-3

Class 2

External reset possible

With fuse

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for INTERBUS

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.