Width45mm
Height206mm
Depth149.5mm
Rated operation current Ie4A
Rated operation power at AC-3, 400 V3.6kW
Number of indicator lights0
Number of auxiliary contacts as normally open contact1
Supporting protocol for TCP/IPNo
Suitable for emergency stopNo
Supporting protocol for Data-HighwayNo
With transformerNo
Supporting protocol for CANNo
Overload release current setting1 - 4A
Number of command positions0
Number of auxiliary contacts as normally closed contact0
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for LONNo
External reset possibleNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleNo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Supporting protocol for SERCOSNo
Release classAdjustable
With fuseNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
With short-circuit releaseYes
Supporting protocol for PROFIsafeNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection of main circuitScrew connection
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Rated operation power at AC-3, 230 V, 3-phase0.75kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Supporting protocol for PROFINET CBANo
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Type of motor starterDirect online starter (DOL)
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Rated operation current at AC-3, 400 V4A
Supporting protocol for EtherNet/IPNo
Rated conditional short-circuit current, type 2, 400 V100000A
Rated conditional short-circuit current, type 2, 230 V100000A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DME-4-M17(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Height

206mm

Depth

149.5mm

Rated operation current Ie

4A

Rated operation power at AC-3, 400 V

3.6kW

Number of indicator lights

0

Number of auxiliary contacts as normally open contact

1

Supporting protocol for TCP/IP

Suitable for emergency stop

Supporting protocol for Data-Highway

With transformer

Supporting protocol for CAN

Overload release current setting

1 .. 4A

Number of command positions

0

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for LON

External reset possible

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rail mounting possible

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for SUCONET

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Release class

Adjustable

With fuse

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

With short-circuit release

Supporting protocol for PROFIsafe

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Type of electrical connection of main circuit

Screw connection

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Rated operation power at AC-3, 230 V, 3-phase

0.75kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

DC

Supporting protocol for PROFINET CBA

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for SafetyBUS p

Type of motor starter

Direct online starter (DOL)

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Rated operation current at AC-3, 400 V

4A

Supporting protocol for EtherNet/IP

Rated conditional short-circuit current, type 2, 400 V

100000A

Rated conditional short-circuit current, type 2, 230 V

100000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A