Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-DME-4-M17(24VDC)

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Width
45mm
Height
206mm
Depth
149.5mm
Rated operation current Ie
4A
Rated operation power at AC-3, 400 V
3.6kW
Number of indicator lights
0
Number of auxiliary contacts as normally open contact
1
Supporting protocol for TCP/IP
Suitable for emergency stop
Supporting protocol for Data-Highway
With transformer
Supporting protocol for CAN
Overload release current setting
1 .. 4A
Number of command positions
0
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for Modbus
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for LON
External reset possible
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rail mounting possible
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for SUCONET
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for other bus systems
Supporting protocol for DeviceNet
Supporting protocol for SERCOS
Release class
Adjustable
With fuse
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
With short-circuit release
Supporting protocol for PROFIsafe
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for AS-Interface Safety at Work
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP)
IP20
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Rated operation power at AC-3, 230 V, 3-phase
0.75kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Voltage type for actuating
DC
Supporting protocol for PROFINET CBA
Rated power, 575 V, 60 Hz, 3-phase
0kW
Supporting protocol for SafetyBUS p
Type of motor starter
Direct online starter (DOL)
Ambient temperature, upper operating limit
55°C
Temperature compensated overload protection
Rated operation current at AC-3, 400 V
4A
Supporting protocol for EtherNet/IP
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated conditional short-circuit current, type 2, 230 V
100000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (NEMA)
Other
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A