Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Yes
Rated operation power at AC-3, 230 V, 3-phase
3kW
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated control supply voltage Us at DC
24 - 24V
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 60HZ
0 - 0V
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Temperature compensated overload protection
Yes
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 400 V
5.5kW
Ambient temperature, upper operating limit
55°C
Overload release current setting
8 - 12A
Number of auxiliary contacts as normally closed contact
1
Rated operation current at AC-3, 400 V
12A
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated conditional short-circuit current, type 2, 230 V
100000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Voltage type for actuating
DC
Release class
Adjustable
Rated operation current Ie
11.3A
Type of motor starter
Direct online starter (DOL)
With transformer
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for emergency stop
No
Rail mounting possible
No
Number of command positions
0
With fuse
No
External reset possible
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Degree of protection (NEMA)
Other
Supporting protocol for ASI
No
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for CAN
No
Number of indicator lights
0
Supporting protocol for INTERBUS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Type of electrical connection of main circuit
Screw connection
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Height
206mm
Degree of protection (IP)
IP20
Width
45mm
Depth
149.5mm
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
MSC-DMEA-12-M17(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Rated operation power at AC-3, 230 V, 3-phase
3kW
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at DC
24 .. 24V
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Temperature compensated overload protection
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 400 V
5.5kW
Ambient temperature, upper operating limit
55°C
Overload release current setting
8 .. 12A
Number of auxiliary contacts as normally closed contact
1
Rated operation current at AC-3, 400 V
12A
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated conditional short-circuit current, type 2, 230 V
100000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Voltage type for actuating
DC
Release class
Adjustable
Rated operation current Ie
11.3A
Type of motor starter
Direct online starter (DOL)
With transformer
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for emergency stop
Rail mounting possible
Number of command positions
0
With fuse
External reset possible
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Degree of protection (NEMA)
Other
Supporting protocol for ASI
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for CAN
Number of indicator lights
0
Supporting protocol for INTERBUS
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Type of electrical connection of main circuit
Screw connection
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Height
206mm
Degree of protection (IP)
IP20
Width
45mm
Depth
149.5mm
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
We use cookies to enhance your experience.