Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth149.5mm
Number of command positions0
With transformerNo
Number of indicator lights0
Overload release current setting8 - 12A
Rated operation power at AC-3, 400 V5.5kW
Supporting protocol for TCP/IPNo
Suitable for emergency stopNo
Width45mm
Number of auxiliary contacts as normally open contact0
Height206mm
Supporting protocol for LONNo
Number of auxiliary contacts as normally closed contact1
Rated operation current Ie11.3A
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for PROFIsafeNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET IONo
With short-circuit releaseYes
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for DeviceNetNo
With fuseNo
Type of electrical connection of main circuitScrew connection
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for EtherNet/IPNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for Foundation FieldbusNo
External reset possibleNo
Release classAdjustable
Supporting protocol for ModbusNo
Rail mounting possibleNo
Supporting protocol for SUCONETNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Temperature compensated overload protectionYes
Rated operation current at AC-3, 400 V12A
Degree of protection (NEMA)Other
Coordination class according to IEC 60947-4-3Class 2
Type of motor starterDirect online starter (DOL)
Rated conditional short-circuit current, type 2, 230 V100000A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V100000A
Rated operation power at AC-3, 230 V, 3-phase3kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated power, 575 V, 60 Hz, 3-phase0kW
Ambient temperature, upper operating limit55°C
Voltage type for actuatingDC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DMEA-12-M17(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Depth

149.5mm

Number of command positions

0

With transformer

Number of indicator lights

0

Overload release current setting

8 .. 12A

Rated operation power at AC-3, 400 V

5.5kW

Supporting protocol for TCP/IP

Suitable for emergency stop

Width

45mm

Number of auxiliary contacts as normally open contact

0

Height

206mm

Supporting protocol for LON

Number of auxiliary contacts as normally closed contact

1

Rated operation current Ie

11.3A

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for PROFIsafe

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Supporting protocol for PROFINET IO

With short-circuit release

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for DeviceNet

With fuse

Type of electrical connection of main circuit

Screw connection

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for EtherNet/IP

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for Foundation Fieldbus

External reset possible

Release class

Adjustable

Supporting protocol for Modbus

Rail mounting possible

Supporting protocol for SUCONET

Rated power, 460 V, 60 Hz, 3-phase

0kW

Supporting protocol for SafetyBUS p

Temperature compensated overload protection

Rated operation current at AC-3, 400 V

12A

Degree of protection (NEMA)

Other

Coordination class according to IEC 60947-4-3

Class 2

Type of motor starter

Direct online starter (DOL)

Rated conditional short-circuit current, type 2, 230 V

100000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

100000A

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Ambient temperature, upper operating limit

55°C

Voltage type for actuating

DC

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.