Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact1
Rated operation current Ie16.7A
Width45mm
Depth149.5mm
Suitable for emergency stopNo
Rated operation power at AC-3, 400 V7.5kW
Number of auxiliary contacts as normally open contact0
Height206mm
With transformerNo
Number of command positions0
Overload release current setting8 - 32A
Supporting protocol for ASINo
Number of indicator lights0
Supporting protocol for TCP/IPNo
Supporting protocol for LONNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUSNo
Rail mounting possibleNo
Supporting protocol for CANNo
With short-circuit releaseYes
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
With fuseNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Release classAdjustable
External reset possibleNo
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for EtherNet/IPNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Type of motor starterDirect online starter (DOL)
Supporting protocol for PROFINET IONo
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Coordination class according to IEC 60947-4-3Class 2
Rated operation current at AC-3, 400 V17A
Rated operation power at AC-3, 230 V, 3-phase4kW
Temperature compensated overload protectionYes
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 2, 400 V100000A
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Supporting protocol for PROFINET CBANo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V100000A
Voltage type for actuatingDC
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-DMEA-32-M17(24VDC)

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact

1

Rated operation current Ie

16.7A

Width

45mm

Depth

149.5mm

Suitable for emergency stop

Rated operation power at AC-3, 400 V

7.5kW

Number of auxiliary contacts as normally open contact

0

Height

206mm

With transformer

Number of command positions

0

Overload release current setting

8 .. 32A

Supporting protocol for ASI

Number of indicator lights

0

Supporting protocol for TCP/IP

Supporting protocol for LON

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for INTERBUS

Rail mounting possible

Supporting protocol for CAN

With short-circuit release

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

With fuse

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Release class

Adjustable

External reset possible

Degree of protection (IP)

IP20

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for EtherNet/IP

Type of electrical connection of main circuit

Screw connection

Supporting protocol for Foundation Fieldbus

Type of motor starter

Direct online starter (DOL)

Supporting protocol for PROFINET IO

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for SafetyBUS p

Coordination class according to IEC 60947-4-3

Class 2

Rated operation current at AC-3, 400 V

17A

Rated operation power at AC-3, 230 V, 3-phase

4kW

Temperature compensated overload protection

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 2, 400 V

100000A

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Supporting protocol for PROFINET CBA

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

100000A

Voltage type for actuating

DC

Supporting protocol for PROFIsafe