Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact1
Width45mm
Depth149.5mm
Suitable for emergency stopNo
Number of auxiliary contacts as normally open contact0
Height206mm
With transformerNo
Number of command positions0
Supporting protocol for ASINo
Number of indicator lights0
Supporting protocol for TCP/IPNo
Supporting protocol for LONNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUSNo
Rail mounting possibleNo
Supporting protocol for CANNo
With short-circuit releaseYes
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
With fuseNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Release classAdjustable
External reset possibleNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for EtherNet/IPNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for SafetyBUS pNo
Coordination class according to IEC 60947-4-3Class 2
Rated operation power at AC-3, 230 V, 3-phase4kW
Temperature compensated overload protectionYes
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 2, 400 V100000A
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Supporting protocol for PROFINET CBANo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V100000A
Voltage type for actuatingDC
Supporting protocol for PROFIsafeNo
Rated operation power at AC-3, 400 V7.5kW
Rated operation current Ie16.7A
Overload release current setting8 - 32A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V17A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user