Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
16.7A
Rated control supply voltage Us at AC 50HZ
0 - 0V
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Yes
Rated control supply voltage Us at DC
24 - 24V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Voltage type for actuating
DC
Rated operation current at AC-3, 400 V
17A
Rail mounting possible
No
Rated operation power at AC-3, 400 V
7.5kW
Overload release current setting
8 - 32A
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
100000A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
1
Supporting protocol for CAN
No
Rated operation power at AC-3, 230 V, 3-phase
4kW
Degree of protection (NEMA)
Other
Release class
Adjustable
With transformer
No
Temperature compensated overload protection
Yes
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Suitable for emergency stop
No
Number of command positions
0
Supporting protocol for DeviceNet
No
Coordination class according to IEC 60947-4-3
Class 2
With fuse
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFIBUS
No
Supporting protocol for TCP/IP
No
Supporting protocol for EtherNet/IP
No
Degree of protection (IP)
IP20
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
External reset possible
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for Modbus
No
Supporting protocol for SERCOS
No
Type of electrical connection of main circuit
Screw connection
Supporting protocol for LON
No
Number of indicator lights
0
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for ASI
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
Yes
Depth
149.5mm
Width
45mm
Height
206mm
From same serie
MSC-DMEA-32-M17(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
16.7A
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Voltage type for actuating
DC
Rated operation current at AC-3, 400 V
17A
Rail mounting possible
Rated operation power at AC-3, 400 V
7.5kW
Overload release current setting
8 .. 32A
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 2, 400 V
100000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
100000A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
1
Supporting protocol for CAN
Rated operation power at AC-3, 230 V, 3-phase
4kW
Degree of protection (NEMA)
Other
Release class
Adjustable
With transformer
Temperature compensated overload protection
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Suitable for emergency stop
Number of command positions
0
Supporting protocol for DeviceNet
Coordination class according to IEC 60947-4-3
Class 2
With fuse
Supporting protocol for PROFINET CBA
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Supporting protocol for EtherNet/IP
Degree of protection (IP)
IP20
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
External reset possible
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for Modbus
Supporting protocol for SERCOS
Type of electrical connection of main circuit
Screw connection
Supporting protocol for LON
Number of indicator lights
0
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for ASI
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Depth
149.5mm
Width
45mm
Height
206mm
From same serie