Technical specifications

Rated permanent current Iu100A
Rated voltage690 - 690V
Overload release current setting40 - 100A
Adjustment range short-term delayed short-circuit release2 - 10A
Adjustment range undelayed short-circuit release2 - 18A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device plug-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Integrated earth fault protectionNo
Type of electrical connection of main circuitOther
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalNo
Number of poles4
Motor drive integratedNo
With switched-off indicatorNo
Type of control elementRocker lever
Position of connection for main current circuitConnection at separate chassis part
With integrated under voltage releaseNo
Complete device with protection unitYes
Motor drive optionalYes
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-4-PX100/VAR-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

100A

Rated voltage

690 .. 690V

Overload release current setting

40 .. 100A

Adjustment range short-term delayed short-circuit release

2 .. 10A

Adjustment range undelayed short-circuit release

2 .. 18A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device plug-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Integrated earth fault protection

Type of electrical connection of main circuit

Other

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Number of poles

4

Motor drive integrated

With switched-off indicator

Type of control element

Rocker lever

Position of connection for main current circuit

Connection at separate chassis part

With integrated under voltage release

Complete device with protection unit

Motor drive optional

Degree of protection (IP)

IP20