Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range undelayed short-circuit release2 - 18A
Overload release current setting64 - 160A
With integrated under voltage releaseNo
Type of electrical connection of main circuitScrew connection
Adjustment range short-term delayed short-circuit release2 - 10A
Rated permanent current Iu160A
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalYes
Position of connection for main current circuitFront side
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally open contact0
Type of control elementRocker lever
Complete device with protection unitYes
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo
Number of poles4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-4-PX160/VAR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range undelayed short-circuit release

2 .. 18A

Overload release current setting

64 .. 160A

With integrated under voltage release

Type of electrical connection of main circuit

Screw connection

Adjustment range short-term delayed short-circuit release

2 .. 10A

Rated permanent current Iu

160A

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally open contact

0

Type of control element

Rocker lever

Complete device with protection unit

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

Number of poles

4

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.