Technical specifications

Rated permanent current Iu100A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Overload release current setting40 - 100A
Type of electrical connection of main circuitOther
Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Position of connection for main current circuitConnection at separate chassis part
Adjustment range undelayed short-circuit release2 - 18A
Number of poles3
Adjustment range short-term delayed short-circuit release2 - 10A
With switched-off indicatorNo
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionYes
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalYes
Device constructionBuilt-in device plug-in technique
Type of control elementRocker lever
Number of auxiliary contacts as normally open contact0
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-PX100-TZ-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

100A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Overload release current setting

40 .. 100A

Type of electrical connection of main circuit

Other

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Connection at separate chassis part

Adjustment range undelayed short-circuit release

2 .. 18A

Number of poles

3

Adjustment range short-term delayed short-circuit release

2 .. 10A

With switched-off indicator

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional

Device construction

Built-in device plug-in technique

Type of control element

Rocker lever

Number of auxiliary contacts as normally open contact

0