Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu160A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
Overload release current setting64 - 160A
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range undelayed short-circuit release2 - 18A
Adjustment range short-term delayed short-circuit release2 - 10A
Integrated earth fault protectionYes
Position of connection for main current circuitConnection at separate chassis part
Rated voltage690 - 690V
With switched-off indicatorNo
Motor drive optionalYes
Device constructionBuilt-in device plug-in technique
Type of electrical connection of main circuitOther
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Degree of protection (IP)IP20
Number of poles3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-PX160-TZ-SVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

160A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

Overload release current setting

64 .. 160A

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range undelayed short-circuit release

2 .. 18A

Adjustment range short-term delayed short-circuit release

2 .. 10A

Integrated earth fault protection

Position of connection for main current circuit

Connection at separate chassis part

Rated voltage

690 .. 690V

With switched-off indicator

Motor drive optional

Device construction

Built-in device plug-in technique

Type of electrical connection of main circuit

Other

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Degree of protection (IP)

IP20

Number of poles

3