Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu250A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Overload release current setting100 - 250A
Adjustment range undelayed short-circuit release2 - 12A
Adjustment range short-term delayed short-circuit release2 - 10A
Device constructionBuilt-in device plug-in technique
Integrated earth fault protectionYes
Type of electrical connection of main circuitOther
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
With integrated under voltage releaseNo
Number of poles3
Type of control elementRocker lever
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitConnection at separate chassis part
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Degree of protection (IP)IP20
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-PX250-TZ-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Overload release current setting

100 .. 250A

Adjustment range undelayed short-circuit release

2 .. 12A

Adjustment range short-term delayed short-circuit release

2 .. 10A

Device construction

Built-in device plug-in technique

Integrated earth fault protection

Type of electrical connection of main circuit

Other

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

With integrated under voltage release

Number of poles

3

Type of control element

Rocker lever

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Connection at separate chassis part

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Degree of protection (IP)

IP20

Motor drive optional