Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu250A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Overload release current setting100 - 250A
Degree of protection (IP)IP20
Position of connection for main current circuitConnection at separate chassis part
Type of electrical connection of main circuitOther
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Type of control elementRocker lever
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release2 - 10A
Complete device with protection unitYes
Adjustment range undelayed short-circuit release2 - 12A
Device constructionBuilt-in device plug-in technique
Integrated earth fault protectionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-PX250-TZ-SVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

With integrated under voltage release

Rated permanent current Iu

250A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Overload release current setting

100 .. 250A

Degree of protection (IP)

IP20

Position of connection for main current circuit

Connection at separate chassis part

Type of electrical connection of main circuit

Other

Motor drive integrated

With switched-off indicator

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Type of control element

Rocker lever

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

2 .. 10A

Complete device with protection unit

Adjustment range undelayed short-circuit release

2 .. 12A

Device construction

Built-in device plug-in technique

Integrated earth fault protection