Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range undelayed short-circuit release2 - 800A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting252 - 630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementRocker lever
Rated permanent current Iu630A
Number of poles4
Complete device with protection unitYes
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
With switched-off indicatorNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-4-AX630/VAR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range undelayed short-circuit release

2 .. 800A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

252 .. 630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Type of control element

Rocker lever

Rated permanent current Iu

630A

Number of poles

4

Complete device with protection unit

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

DIN rail (top hat rail) mounting optional

Motor drive optional

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Position of connection for main current circuit

Front side

With integrated under voltage release

With switched-off indicator

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.