Technical specifications

Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Overload release current setting160 - 400A
Device constructionBuilt-in device fixed built-in technique
With integrated under voltage releaseNo
Adjustment range undelayed short-circuit release2 - 12A
Rated permanent current Iu400A
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Type of electrical connection of main circuitScrew connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release2 - 10A
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Number of poles4
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo
Type of control elementRocker lever
Position of connection for main current circuitFront side
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-4-VX400

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Overload release current setting

160 .. 400A

Device construction

Built-in device fixed built-in technique

With integrated under voltage release

Adjustment range undelayed short-circuit release

2 .. 12A

Rated permanent current Iu

400A

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Screw connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

2 .. 10A

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Number of poles

4

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

Type of control element

Rocker lever

Position of connection for main current circuit

Front side