  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
DIN rail (top hat rail) mounting optionalNo
Overload release current setting160 - 400A
With switched-off indicatorNo
Type of electrical connection of main circuitOther
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release2 - 10A
With integrated under voltage releaseNo
Device constructionBuilt-in device plug-in technique
Number of auxiliary contacts as normally open contact0
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
Number of poles4
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release2 - 12A
Degree of protection (IP)IP20
Motor drive optionalYes
Rated permanent current Iu400A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-4-VX400/VAR-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

DIN rail (top hat rail) mounting optional

Overload release current setting

160 .. 400A

With switched-off indicator

Type of electrical connection of main circuit

Other

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

2 .. 10A

With integrated under voltage release

Device construction

Built-in device plug-in technique

Number of auxiliary contacts as normally open contact

0

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

Number of poles

4

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

2 .. 12A

Degree of protection (IP)

IP20

Motor drive optional

Rated permanent current Iu

400A