Technical specifications

Rated permanent current Iu630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range undelayed short-circuit release2 - 800A
Rated voltage690 - 690V
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Complete device with protection unitYes
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Motor drive optionalYes
Overload release current setting252 - 630A
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release0 - 0A
With switched-off indicatorNo
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Number of poles3
Type of control elementRocker lever
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-AX630

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range undelayed short-circuit release

2 .. 800A

Rated voltage

690 .. 690V

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Complete device with protection unit

Position of connection for main current circuit

Front side

With integrated under voltage release

Degree of protection (IP)

IP20

Motor drive optional

Overload release current setting

252 .. 630A

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

With switched-off indicator

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Number of poles

3

Type of control element

Rocker lever

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.