Technical specifications

Rated permanent current Iu400A
Overload release current setting160 - 400A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release2 - 10A
Adjustment range undelayed short-circuit release2 - 12A
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Number of poles3
DIN rail (top hat rail) mounting optionalNo
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementRocker lever
With integrated under voltage releaseNo
Complete device with protection unitYes
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
Position of connection for main current circuitFront side
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP20
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-PX400

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

400A

Overload release current setting

160 .. 400A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

2 .. 10A

Adjustment range undelayed short-circuit release

2 .. 12A

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Number of poles

3

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

Type of control element

Rocker lever

With integrated under voltage release

Complete device with protection unit

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Position of connection for main current circuit

Front side

Device construction

Built-in device fixed built-in technique

Degree of protection (IP)

IP20