Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu400A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Number of poles3
Adjustment range short-term delayed short-circuit release2 - 10A
Adjustment range undelayed short-circuit release2 - 12A
Overload release current setting160 - 400A
Position of connection for main current circuitConnection at separate chassis part
Complete device with protection unitYes
Type of electrical connection of main circuitOther
Type of control elementRocker lever
Motor drive integratedNo
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
With switched-off indicatorNo
Device constructionBuilt-in device slide-in technique (withdrawable)
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-PX400-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

400A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Number of poles

3

Adjustment range short-term delayed short-circuit release

2 .. 10A

Adjustment range undelayed short-circuit release

2 .. 12A

Overload release current setting

160 .. 400A

Position of connection for main current circuit

Connection at separate chassis part

Complete device with protection unit

Type of electrical connection of main circuit

Other

Type of control element

Rocker lever

Motor drive integrated

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

With switched-off indicator

Device construction

Built-in device slide-in technique (withdrawable)

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.