Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Type of control elementRocker lever
Overload release current setting100 - 250A
Complete device with protection unitYes
Position of connection for main current circuitFront side
Motor drive integratedNo
Number of poles3
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release2 - 10A
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitScrew connection
With switched-off indicatorNo
Degree of protection (IP)IP20
Rated permanent current Iu250A
Rated voltage690 - 690V
Integrated earth fault protectionNo
With integrated under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release2 - 18A
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VX250

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Type of control element

Rocker lever

Overload release current setting

100 .. 250A

Complete device with protection unit

Position of connection for main current circuit

Front side

Motor drive integrated

Number of poles

3

Motor drive optional

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

2 .. 10A

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection

With switched-off indicator

Degree of protection (IP)

IP20

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Integrated earth fault protection

With integrated under voltage release

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

2 .. 18A

Suitable for DIN rail (top hat rail) mounting

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.