  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device plug-in technique
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release500 - 2500A
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitOther
Rated permanent current Iu250A
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range undelayed short-circuit release500 - 4500A
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
Overload release current setting100 - 250A
Rated voltage690 - 690V
Complete device with protection unitYes
Number of poles3
Position of connection for main current circuitFront side
Type of control elementRocker lever
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VX250-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device plug-in technique

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

500 .. 2500A

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Other

Rated permanent current Iu

250A

With integrated under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range undelayed short-circuit release

500 .. 4500A

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Overload release current setting

100 .. 250A

Rated voltage

690 .. 690V

Complete device with protection unit

Number of poles

3

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.