Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu400A
Rated voltage690 - 690V
Overload release current setting160 - 400A
Adjustment range short-term delayed short-circuit release2 - 10A
Adjustment range undelayed short-circuit release2 - 12A
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
With integrated under voltage releaseNo
Type of control elementRocker lever
Number of poles3
Complete device with protection unitYes
Motor drive integratedNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VX400

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

400A

Rated voltage

690 .. 690V

Overload release current setting

160 .. 400A

Adjustment range short-term delayed short-circuit release

2 .. 10A

Adjustment range undelayed short-circuit release

2 .. 12A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

With integrated under voltage release

Type of control element

Rocker lever

Number of poles

3

Complete device with protection unit

Motor drive integrated

Position of connection for main current circuit

Front side

Motor drive optional

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.