Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release2 - 10A
Adjustment range undelayed short-circuit release2 - 12A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Overload release current setting160 - 400A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optionalNo
Type of electrical connection of main circuitOther
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu400A
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
With integrated under voltage releaseNo
With switched-off indicatorNo
Number of poles3
Complete device with protection unitYes
Type of control elementRocker lever
Degree of protection (IP)IP20
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VX400-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

2 .. 10A

Adjustment range undelayed short-circuit release

2 .. 12A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Overload release current setting

160 .. 400A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device slide-in technique (withdrawable)

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Other

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

400A

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

With integrated under voltage release

With switched-off indicator

Number of poles

3

Complete device with protection unit

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Motor drive optional