Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu630A
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device slide-in technique (withdrawable)
With integrated under voltage releaseNo
Motor drive integratedNo
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release2 - 800A
Number of poles3
Integrated earth fault protectionNo
Motor drive optionalYes
Type of electrical connection of main circuitOther
Number of auxiliary contacts as normally open contact0
Rated voltage690 - 690V
Degree of protection (IP)IP20
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release1.5 - 7A
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Number of auxiliary contacts as normally closed contact0
Overload release current setting252 - 630A
Type of control elementRocker lever
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VX630-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

630A

DIN rail (top hat rail) mounting optional

Device construction

Built-in device slide-in technique (withdrawable)

With integrated under voltage release

Motor drive integrated

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

2 .. 800A

Number of poles

3

Integrated earth fault protection

Motor drive optional

Type of electrical connection of main circuit

Other

Number of auxiliary contacts as normally open contact

0

Rated voltage

690 .. 690V

Degree of protection (IP)

IP20

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

1.5 .. 7A

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

252 .. 630A

Type of control element

Rocker lever

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.