Technical specifications

Integrated earth fault protectionYes
Rated voltage690 - 690V
Rated permanent current Iu630A
Device constructionBuilt-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release1.5 - 7A
With switched-off indicatorNo
Overload release current setting252 - 630A
Type of electrical connection of main circuitOther
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
Complete device with protection unitYes
Number of poles3
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Motor drive integratedNo
Adjustment range undelayed short-circuit release1260 - 10080A
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VX630-T-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Integrated earth fault protection

Rated voltage

690 .. 690V

Rated permanent current Iu

630A

Device construction

Built-in device slide-in technique (withdrawable)

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

1.5 .. 7A

With switched-off indicator

Overload release current setting

252 .. 630A

Type of electrical connection of main circuit

Other

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

Complete device with protection unit

Number of poles

3

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Motor drive integrated

Adjustment range undelayed short-circuit release

1260 .. 10080A

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.