Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting100 - 250A
Rated permanent current Iu250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release2 - 10A
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release2 - 12A
DIN rail (top hat rail) mounting optionalYes
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
Number of poles4
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Degree of protection (IP)IP20
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-PX250/VAR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting

100 .. 250A

Rated permanent current Iu

250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

2 .. 10A

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

2 .. 12A

DIN rail (top hat rail) mounting optional

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

Number of poles

4

Position of connection for main current circuit

Front side

With integrated under voltage release

Complete device with protection unit

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device fixed built-in technique

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.