Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu250A
Rated voltage690 - 690V
Overload release current setting100 - 250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release2 - 12A
Integrated earth fault protectionNo
Device constructionBuilt-in device plug-in technique
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release2 - 10A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
Number of poles4
Position of connection for main current circuitFront side
Complete device with protection unitYes
Type of control elementRocker lever
Motor drive integratedNo
Motor drive optionalYes
Degree of protection (IP)IP20
With integrated under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-PX250/VAR-SVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Overload release current setting

100 .. 250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

2 .. 12A

Integrated earth fault protection

Device construction

Built-in device plug-in technique

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

With switched-off indicator

Adjustment range short-term delayed short-circuit release

2 .. 10A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

Number of poles

4

Position of connection for main current circuit

Front side

Complete device with protection unit

Type of control element

Rocker lever

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20

With integrated under voltage release

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.