Technical specifications

Rated permanent current Iu400A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release2 - 11A
Overload release current setting160 - 400A
DIN rail (top hat rail) mounting optionalNo
Type of electrical connection of main circuitOther
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Motor drive integratedNo
Degree of protection (IP)IP20
With switched-off indicatorNo
Number of poles4
Type of control elementRocker lever
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-AX400/VAR-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

400A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

2 .. 11A

Overload release current setting

160 .. 400A

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Other

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Motor drive integrated

Degree of protection (IP)

IP20

With switched-off indicator

Number of poles

4

Type of control element

Rocker lever

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Motor drive optional

Position of connection for main current circuit

Front side

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as normally closed contact

0