Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting160 - 400A
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Integrated earth fault protectionNo
Rated permanent current Iu400A
Type of electrical connection of main circuitFrame clamp
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Adjustment range undelayed short-circuit release2 - 11A
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
With integrated under voltage releaseNo
Number of poles4
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementRocker lever
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Complete device with protection unitYes
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-AX400-BT

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting

160 .. 400A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Integrated earth fault protection

Rated permanent current Iu

400A

Type of electrical connection of main circuit

Frame clamp

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Adjustment range undelayed short-circuit release

2 .. 11A

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

With integrated under voltage release

Number of poles

4

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Complete device with protection unit

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20