Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu400A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release2 - 10A
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorNo
Type of control elementRocker lever
Complete device with protection unitYes
With integrated under voltage releaseNo
Overload release current setting160 - 400A
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release2 - 12A
Number of auxiliary contacts as change-over contact0
Number of poles4
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP20
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-PX400/VAR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

400A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

2 .. 10A

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

With switched-off indicator

Type of control element

Rocker lever

Complete device with protection unit

With integrated under voltage release

Overload release current setting

160 .. 400A

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

2 .. 12A

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP20

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.