Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu400A
Overload release current setting160 - 400A
Adjustment range short-term delayed short-circuit release2 - 10A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally open contact0
Rated voltage690 - 690V
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release2 - 12A
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
Complete device with protection unitYes
Type of control elementRocker lever
With integrated under voltage releaseNo
With switched-off indicatorNo
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
Number of poles4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-VX400/VAR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

400A

Overload release current setting

160 .. 400A

Adjustment range short-term delayed short-circuit release

2 .. 10A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally open contact

0

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Adjustment range undelayed short-circuit release

2 .. 12A

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

Complete device with protection unit

Type of control element

Rocker lever

With integrated under voltage release

With switched-off indicator

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20

Number of poles

4

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.