Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Integrated earth fault protectionYes
Type of electrical connection of main circuitOther
DIN rail (top hat rail) mounting optionalNo
Overload release current setting160 - 400A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device slide-in technique (withdrawable)
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release2 - 10A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release2 - 12A
Rated permanent current Iu400A
With integrated under voltage releaseNo
Number of poles3
Position of connection for main current circuitConnection at separate chassis part
Type of control elementRocker lever
Motor drive integratedNo
Complete device with protection unitYes
Degree of protection (IP)IP20
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-PX400-TAZ-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Integrated earth fault protection

Type of electrical connection of main circuit

Other

DIN rail (top hat rail) mounting optional

Overload release current setting

160 .. 400A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device slide-in technique (withdrawable)

With switched-off indicator

Adjustment range short-term delayed short-circuit release

2 .. 10A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

2 .. 12A

Rated permanent current Iu

400A

With integrated under voltage release

Number of poles

3

Position of connection for main current circuit

Connection at separate chassis part

Type of control element

Rocker lever

Motor drive integrated

Complete device with protection unit

Degree of protection (IP)

IP20

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.