Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu250A
Rated voltage690 - 690V
Device constructionBuilt-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release2 - 10A
Adjustment range undelayed short-circuit release2 - 18A
Overload release current setting100 - 250A
Type of electrical connection of main circuitOther
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Number of poles3
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Integrated earth fault protectionNo
Type of control elementRocker lever
Complete device with protection unitYes
Motor drive integratedNo
Degree of protection (IP)IP20
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VX250-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Device construction

Built-in device slide-in technique (withdrawable)

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

2 .. 10A

Adjustment range undelayed short-circuit release

2 .. 18A

Overload release current setting

100 .. 250A

Type of electrical connection of main circuit

Other

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Position of connection for main current circuit

Front side

With integrated under voltage release

Integrated earth fault protection

Type of control element

Rocker lever

Complete device with protection unit

Motor drive integrated

Degree of protection (IP)

IP20

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.