Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu400A
Number of poles3
Integrated earth fault protectionYes
Overload release current setting160 - 400A
Motor drive optionalYes
Type of electrical connection of main circuitOther
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Device constructionBuilt-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optionalNo
Position of connection for main current circuitFront side
Type of control elementRocker lever
Adjustment range short-term delayed short-circuit release2 - 10A
With switched-off indicatorNo
With integrated under voltage releaseNo
Motor drive integratedNo
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release800 - 4800A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VX400-T-AVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

400A

Number of poles

3

Integrated earth fault protection

Overload release current setting

160 .. 400A

Motor drive optional

Type of electrical connection of main circuit

Other

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Device construction

Built-in device slide-in technique (withdrawable)

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Adjustment range short-term delayed short-circuit release

2 .. 10A

With switched-off indicator

With integrated under voltage release

Motor drive integrated

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

800 .. 4800A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.