Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu630A
Adjustment range short-term delayed short-circuit release1.5 - 7A
Overload release current setting252 - 630A
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release2 - 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Complete device with protection unitYes
Degree of protection (IP)IP20
Type of control elementRocker lever
Motor drive integratedNo
Number of poles3
With switched-off indicatorNo
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VX630

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

630A

Adjustment range short-term delayed short-circuit release

1.5 .. 7A

Overload release current setting

252 .. 630A

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

2 .. 800A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

With integrated under voltage release

Complete device with protection unit

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Motor drive integrated

Number of poles

3

With switched-off indicator

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.