  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Overload release current setting252 - 630A
Rated permanent current Iu630A
Adjustment range short-term delayed short-circuit release1.5 - 7A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release1260 - 10080A
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Number of poles3
With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionYes
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Complete device with protection unitYes
Type of control elementRocker lever
Degree of protection (IP)IP20
Motor drive optionalYes
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalNo
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-VX630-T

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Overload release current setting

252 .. 630A

Rated permanent current Iu

630A

Adjustment range short-term delayed short-circuit release

1.5 .. 7A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

1260 .. 10080A

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Number of poles

3

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Complete device with protection unit

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Motor drive optional

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side