Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Type of electrical connection of main circuitOther
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Number of poles3
Rated permanent current Iu100A
Position of connection for main current circuitConnection at separate chassis part
Overload release current setting40 - 100A
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Degree of protection (IP)IP20
Number of auxiliary contacts as normally open contact0
Rated voltage690 - 690V
Complete device with protection unitYes
Device constructionBuilt-in device plug-in technique
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Integrated earth fault protectionYes
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release2 - 10A
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release2 - 18A
Type of control elementRocker lever
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMS2-PX100-TZ-SVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Type of electrical connection of main circuit

Other

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Rated permanent current Iu

100A

Position of connection for main current circuit

Connection at separate chassis part

Overload release current setting

40 .. 100A

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally open contact

0

Rated voltage

690 .. 690V

Complete device with protection unit

Device construction

Built-in device plug-in technique

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Integrated earth fault protection

With switched-off indicator

Adjustment range short-term delayed short-circuit release

2 .. 10A

Motor drive optional

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

2 .. 18A

Type of control element

Rocker lever

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.