Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

With integrated under voltage releaseNo
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitConnection at separate chassis part
With switched-off indicatorNo
Rated voltage690 - 690V
Motor drive integratedNo
Type of electrical connection of main circuitOther
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release2 - 10A
Rated permanent current Iu250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Type of control elementRocker lever
Overload release current setting100 - 250A
Number of auxiliary contacts as normally closed contact0
Number of poles3
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release2 - 12A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device plug-in technique
Integrated earth fault protectionYes
Motor drive optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMS2-PX250-TZ-SVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

With integrated under voltage release

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Connection at separate chassis part

With switched-off indicator

Rated voltage

690 .. 690V

Motor drive integrated

Type of electrical connection of main circuit

Other

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

2 .. 10A

Rated permanent current Iu

250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Type of control element

Rocker lever

Overload release current setting

100 .. 250A

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

2 .. 12A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device plug-in technique

Integrated earth fault protection

Motor drive optional

Complete device with protection unit