  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting160 - 400A
Rated voltage690 - 690V
Rated permanent current Iu400A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Type of electrical connection of main circuitOther
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device slide-in technique (withdrawable)
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release2 - 11A
With integrated under voltage releaseNo
Number of poles4
Position of connection for main current circuitFront side
Type of control elementRocker lever
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMS3-4-AX400/VAR-AVE

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting

160 .. 400A

Rated voltage

690 .. 690V

Rated permanent current Iu

400A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Type of electrical connection of main circuit

Other

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device slide-in technique (withdrawable)

With switched-off indicator

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

2 .. 11A

With integrated under voltage release

Number of poles

4

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Complete device with protection unit

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20