Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu630A
Number of auxiliary contacts as normally open contact0
Number of poles4
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Motor drive integratedNo
Overload release current setting252 - 630A
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Motor drive optionalYes
With switched-off indicatorNo
Adjustment range undelayed short-circuit release2 - 800A
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitOther
Type of control elementRocker lever
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device slide-in technique (withdrawable)
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMS3-4-AX630/VAR-AVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

630A

Number of auxiliary contacts as normally open contact

0

Number of poles

4

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Motor drive integrated

Overload release current setting

252 .. 630A

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Motor drive optional

With switched-off indicator

Adjustment range undelayed short-circuit release

2 .. 800A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Other

Type of control element

Rocker lever

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device slide-in technique (withdrawable)

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.