Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu630A
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Type of control elementRocker lever
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionYes
Adjustment range short-term delayed short-circuit release1.5 - 7A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Degree of protection (IP)IP20
Type of electrical connection of main circuitScrew connection
Number of poles4
Overload release current setting252 - 630A
Adjustment range undelayed short-circuit release1260 - 10080A
With switched-off indicatorNo
Motor drive integratedNo
Complete device with protection unitYes
Rated voltage690 - 690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMS3-4-VX630/VAR-T

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

630A

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

1.5 .. 7A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Screw connection

Number of poles

4

Overload release current setting

252 .. 630A

Adjustment range undelayed short-circuit release

1260 .. 10080A

With switched-off indicator

Motor drive integrated

Complete device with protection unit

Rated voltage

690 .. 690V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.