Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting252 - 630A
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Motor drive integratedNo
Rated voltage690 - 690V
Type of electrical connection of main circuitOther
Type of control elementRocker lever
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release1.5 - 7A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release2 - 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Rated permanent current Iu630A
Number of poles4
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Motor drive optionalYes
Device constructionBuilt-in device slide-in technique (withdrawable)
Integrated earth fault protectionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMS3-4-VX630/VAR-T-AVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting

252 .. 630A

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Motor drive integrated

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Other

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

1.5 .. 7A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

2 .. 800A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Rated permanent current Iu

630A

Number of poles

4

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Motor drive optional

Device construction

Built-in device slide-in technique (withdrawable)

Integrated earth fault protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.