Technical specifications

With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
Number of poles3
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release1.5 - 7A
Rated permanent current Iu630A
Motor drive integratedNo
Adjustment range undelayed short-circuit release1260 - 10080A
Rated voltage690 - 690V
Type of control elementRocker lever
Position of connection for main current circuitConnection at separate chassis part
Overload release current setting252 - 630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Type of electrical connection of main circuitOther
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Degree of protection (IP)IP20
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes
Integrated earth fault protectionNo
Device constructionBuilt-in device plug-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMS3-PX630-SVE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

1.5 .. 7A

Rated permanent current Iu

630A

Motor drive integrated

Adjustment range undelayed short-circuit release

1260 .. 10080A

Rated voltage

690 .. 690V

Type of control element

Rocker lever

Position of connection for main current circuit

Connection at separate chassis part

Overload release current setting

252 .. 630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Type of electrical connection of main circuit

Other

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Degree of protection (IP)

IP20

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Motor drive optional

Integrated earth fault protection

Device construction

Built-in device plug-in technique

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.