Rated permanent current Iu1.6A
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Overload release current setting1.6 - 1.6A
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
Rated voltage690 - 690V
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitOther
With integrated under voltage releaseNo
Power loss4.92W
Adjustment range undelayed short-circuit release32 - 32A
Number of auxiliary contacts as normally closed contact0
Complete device with protection unitNo
Type of control elementTurn button
With switched-off indicatorNo
Number of poles3
Motor drive optionalNo
Degree of protection (IP)IP20
Type of electrical connection of main circuitSpring clamp connection
Motor drive integratedNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PKZM0-1,6-T-PI

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

1.6A

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Overload release current setting

1.6 .. 1.6A

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Rated voltage

690 .. 690V

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Other

With integrated under voltage release

Power loss

4.92W

Adjustment range undelayed short-circuit release

32 .. 32A

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Type of control element

Turn button

With switched-off indicator

Number of poles

3

Motor drive optional

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Spring clamp connection

Motor drive integrated

Related products