Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu20A
Integrated earth fault protectionNo
Type of electrical connection of main circuitSpring clamp connection
DIN rail (top hat rail) mounting optionalYes
Rated voltage690 - 690V
Power loss5.68W
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release380 - 380A
Overload release current setting20 - 20A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release0 - 0A
With integrated under voltage releaseNo
Type of control elementTurn button
Number of auxiliary contacts as normally closed contact0
Number of poles3
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Position of connection for main current circuitOther
Complete device with protection unitNo
With switched-off indicatorNo
Motor drive optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PKZM0-20-T-PI

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

20A

Integrated earth fault protection

Type of electrical connection of main circuit

Spring clamp connection

DIN rail (top hat rail) mounting optional

Rated voltage

690 .. 690V

Power loss

5.68W

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

380 .. 380A

Overload release current setting

20 .. 20A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

With integrated under voltage release

Type of control element

Turn button

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Position of connection for main current circuit

Other

Complete device with protection unit

With switched-off indicator

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Degree of protection (IP)

IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.