Technical specifications

Voltage typeAC
Built-in depth72mm
Rated voltage400V
Rated current13A
Number of protected poles3
Explosion-proofNo
Current limiting class3
Release characteristicC
Degree of protection (IP)IP20
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Power loss7.2W
Over voltage category3
Pollution degree3
Width in number of modular spacings2
Rated impulse withstand voltage Uimp4kV
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V4.5kA
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core16 - 16mm²
Connectable conductor cross section multi-wired10 - 10mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V4.5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V4.5kA
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW90071

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Voltage type

AC

Built-in depth

72mm

Rated voltage

400V

Rated current

13A

Number of protected poles

3

Explosion-proof

Current limiting class

3

Release characteristic

C

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Power loss

7.2W

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

2

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

4.5kA

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

16 .. 16mm²

Connectable conductor cross section multi-wired

10 .. 10mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

4.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

4.5kA

Additional equipment possible