Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated voltage400V
Rated insulation voltage Ui500V
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Frequency50 - 60Hz
Power loss6.81W
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Pollution degree3
Current limiting class1
Over voltage category3
Additional equipment possibleYes
Degree of protection (IP)IP20
Width in number of modular spacings2
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired10 - 10mm²
Connectable conductor cross section solid-core16 - 16mm²
Explosion-proofNo
Rated current20A
Release characteristicC
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW90268 | Compact MCB 3P C20 6KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated voltage

400V

Rated insulation voltage Ui

500V

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Frequency

50 .. 60Hz

Power loss

6.81W

Flush-mounted installation

Concurrently switching neutral conductor

Pollution degree

3

Current limiting class

1

Over voltage category

3

Additional equipment possible

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

10 .. 10mm²

Connectable conductor cross section solid-core

16 .. 16mm²

Explosion-proof

Rated current

20A

Release characteristic

C

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.