Built-in depth72mm
Power loss10.35W
Rated insulation voltage Ui500V
Current limiting class1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Width in number of modular spacings2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Over voltage category3
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Explosion-proofNo
Flush-mounted installationNo
Additional equipment possibleYes
Pollution degree3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired10 - 10mm²
Voltage typeAC
Rated voltage400V
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core16 - 16mm²
Ambient temperature during operating-25 - 60°C
Rated current32A
Release characteristicC
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW90270 | Compact MCB 3P C32 6KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Power loss

10.35W

Rated insulation voltage Ui

500V

Current limiting class

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Over voltage category

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Explosion-proof

Flush-mounted installation

Additional equipment possible

Pollution degree

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

10 .. 10mm²

Voltage type

AC

Rated voltage

400V

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

16 .. 16mm²

Ambient temperature during operating

-25 .. 60°C

Rated current

32A

Release characteristic

C

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA