Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth72mm
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Current limiting class3
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Number of protected poles3
Rated voltage400V
Voltage typeAC
Pollution degree3
Flush-mounted installationNo
Power loss7.2W
Degree of protection (IP)IP20
Over voltage category3
Connectable conductor cross section solid-core16 - 16mm²
Connectable conductor cross section multi-wired10 - 10mm²
Explosion-proofNo
Rated current13A
Release characteristicC
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GW90271 | Compact MCB 3P C13 6KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Current limiting class

3

Width in number of modular spacings

2

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Number of protected poles

3

Rated voltage

400V

Voltage type

AC

Pollution degree

3

Flush-mounted installation

Power loss

7.2W

Degree of protection (IP)

IP20

Over voltage category

3

Connectable conductor cross section solid-core

16 .. 16mm²

Connectable conductor cross section multi-wired

10 .. 10mm²

Explosion-proof

Rated current

13A

Release characteristic

C

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA